Applications
- Water Technology
- Water Quality Monitoring Systems
- Process Monitoring
- Process Control
Features
- cost-efficient measurement of process parameters
- display for measuring values and clear calibration instructions
- simultaneous temperature measurement
- 2 free scaleable analogue outputs and 1 relay output
- USB interface and PC software
- modular DIN rail mounted case
- networking with display unit for 8 measuring values
- firmware update via USB
The transmitter series MV 3000 and MV 4000 are excellently suited for continuous measurements of one or more parameters in
connection with process control units, data loggers, -printers or visualisation systems. They are characterised by high
flexibility and simple handling. Calibrations can be done directly on transmitter. An additional display on MV 4000
simplifies measuring value checks, calibrations and makes each transmitter to a stand-alone measuring instrument.
All transmitters can be connected with the display unit AZ 3000. In this way the customer gets a complete multiparameter
measuring system with data logger and fieldbus interface RS-485.
Simple software features configuring with logging of configuration parameters, calibration as well as displaying and
recording of measuring values directly on PC using USB interface. Additionally the series MV 4000 allows actualisation
of firmware via flash update.
- automatically with Pt 1000 or fixed temperature
Kalibrierung
- using 2 configurable buttons or PC software
Signalisation
- LED: measuring value stability for calibration, measuring, errors
- graphic LCD, 48 x 64 pixel, back-lighted,
- display for 3 values (value 1, value 2 and temperature value)
- clear calibration instructions
Controller outputs
- 1 limit relay, NOC, 24 V AC/DC, max. 1 A
- 2 x 0(4) ... 20 mA oder 2 x 0 ... 5 V
Interfaces
- MV 4000: USB (optional RS-232)
- MV 3000: RS-232
- for configuration, calibration and data logger
Dimensions
- 22.5x99x114.5 mm (W x H x D)
- via PC-interface (only MV 4000)
Power supply
- 15 ... 24 V AC / DC, ca. 1.5 VA
- plastic case for mounting on rail tracks DIN EN 50022-35
- protection IP 40
- EN 61326 class B
Type | Component | Description | |
MV 40XX | Transmitter |
|
|
MV 40XX-U | Transmitter |
|
|
MV 30XX | Transmitter |
|
|
MV 30XX-U | Transmitter |
|
|
with Display | without Display | Measuring range | Resolution | Temperature measurement |
MV 4010 | MV 3010 | pH value
|
pH 0,01 | -10 ... 130 °C res. 0,1 °C |
MV 4015 | MV 3015 | Redox potential
|
-10 ... 130 °C res. 0,1 °C |
|
MV 4016 | MV 3016 | Ion concentration
|
pH 0,01 | -10 ... 130 °C res. 0,1 °C |
MV 4020 | MV 3020 | Conductivity (2-pol)
|
0,1 µS/cm 1,0 µS 0,01 mS/cm 0,1 mS/cm |
-10 ... 130 °C res. 0,1 °C |
MV 4025 | MV 3025 | Conductivity (4-pol)
|
0,1 µS/cm 1,0 µS 0,01 mS/cm 0,1 mS/cm |
-10 ... 130 °C res. 0,1 °C |
MV 4030 | MV 3030 | Dissolved oxygen
|
0,1 % 0,01 mg/l |
-10 ... 130 °C res. 0,1 °C |
MV 4060 | MV 3060 | Concentration (chlorine, dioxide, ...)
|
0,01 mg/l | -10 ... 130 °C res. 0,1 °C |